INTRODUCTION

This series is a kind of high-performance and high-intelligence equipment for sterilizing, leak detecting and cleaning, which adopts colorful touching screen and PLC,applicable to treating of ampoule, oral medicine, small infusion bottle, etc. After sterilization, by means of vacuum or vacuum plus water, the detecting rate of waster is assured to be 100%. Finally washing treatment is carried out with pure water to ensure surface of bottle clean and uncontaminated.


SIZE & UTILITIES

Model

Overall Size   L*W*H(mm)

Chamber   Size L*W*H(mm)

Steam Consumption   (kg/cycle)

Compressed   Air Consumption (m3/cycle)

Cooling Water   Consumption (kg/cycle)

Loading Cart   (pcs)

Power (KW)

Net Weight   (kg)

AM-0.36

1195*1220*1720

1000*600*600

55

0.5

300

3

760

AM-0.6

1245*1300*1880

1050*680*850

75

0.8

400

3

1100

AM-1.2

1695*1370*1960

1500*750*1100

85

1.5

800

2

4

1900

AM-1.8

2445*1370*1960

2250*750*1100

100

2.0

1200

3

4

2450

AM-2.5

3195*1370*1960

3000*750*1100

180

3.0

1500

4

6

2800

AM-5.0

3635*1800*2200

3400*1000*1500

300

5.5

2500

4

6

4500



STRUCTURE & CAPABILITY & CHARACTERISTICS

  • Vessels is designed to the China National Standard -GB150《Steel Pressure Vessel》

  • National patent door interlock device.

  • National patent sealing technology- closed inflatable seal ring with compressed air.

  • Control system is integrated by PLC+ HMI, advanced function for recording, printing and storing.

  • The GMP validation port is provided for insertion of 16 temperature sensors for validation.

  • Unique spraying cooling device

  • Independent temperature monitoring system




MAIN PARAMETERS AND UTILITIES

Design Pressure

0.245Mpa

Vacuum

-0.095Mpa

Working Pressure

0.22Mpa

Steam Source Pressure

0.4-0.6Mpa

Design Temperature

139℃

Water Source Pressure

0.2-0.3Mpa

Working Temperature

134℃

Compressed Air Pressure

0.6-0.8Mpa

Heat equilibrium

≤±1℃






LOADING

Model

1ml

2ml

5ml

10ml

20ml

AM-0.36

37440

26100

10000

6800

3700

AM-0.6

74880

52224

20160

13680

7500

AM-1.2

127816

81664

33984

22400

11424

AM-1.8

191724

122496

50976

33600

17136

AM-2.5

255632

163328

67968

44800

22848

AM-5.0

605568

380160

169344

98208

14040